On many construction sites, diesel is still sprayed onto skips, rollers and tools as a release agent. It is cheap and readily available. However, diesel is problematic as a release agent: for health, for soil and water, for the mix – and for the measurement values that will also count for rolled asphalt from 2027 onwards. A laboratory measurement now shows just how big the difference is.
The disadvantages of diesel as a release agent
- Health: Under the CLP Regulation, diesel is classified, amongst other things, as flammable, harmful if inhaled, a skin irritant and suspected of causing cancer. When sprayed onto hot surfaces, workers inhale vapours and mist.
- More vapours and aerosols: In laboratory tests, the measured value for diesel was approximately five times higher than that for the mixture without a release agent. BG BAU therefore advises against the use of mineral oil-based release agents in its industry-specific solution for rolled asphalt.
- Fire hazard: The flash point of diesel is 55 °C and above, which is well below the temperature of hot tarmac and hot machine parts.
- Soil and water: Diesel is highly hazardous to water (WGK 2) and toxic to aquatic organisms. Any diesel that drips from the trough, roller or tool ends up in the ground or in the sewer system.
- Mixture: Diesel dissolves bitumen. If it drips onto the mix or into the trough, it can soften the binder in places.
- Transport and storage: Diesel is classified as a dangerous good under the ADR and must be transported and stored accordingly.
Laboratory test: Diesel versus Antistick ECO
TPA GmbH (Labor Hamburg) carried out measurements on behalf of Eco-Nova to determine the extent to which release agents affect the vapours and aerosols from hot asphalt mix. The study was based on the method developed by the DGUV Institute for Occupational Safety and Health (IFA Workbook 6305, Method 1). A SMA 8 S chip-sealer was agitated at 150 °C in a laboratory mixer, whilst the air above it was extracted through a glass fibre filter (aerosols) and an XAD-2 cartridge (vapours). The samples were analysed by the ANECO Institute for Occupational Safety and Health.
| SMA 8 S mix, 150 °C | Total measured value for vapours and aerosols | compared with diesel |
|---|---|---|
| without release agent (reference) | 104.0 mg/m³ | –81 % |
| with Antistick ECO 150 LV | 105.9 mg/m³ | –80 % |
| with Antistick ECO 150 | 120.6 mg/m³ | –78 % |
| with Antistick ECO 170 | 141.1 mg/m³ | –74 % |
| with diesel | 543.5 mg/m³ | – |
The result: With diesel, the total measured value was 543.5 mg/m³ – around five times higher than without a release agent. With Antistick ECO, the values were 74 to 80 % lower. Antistick ECO 150 LV, at 105.9 mg/m³, was almost on a par with the mixture without a release agent.
Work on a building site is never carried out entirely without a release agent. It is therefore crucial to compare it with what is normally used – and there is a world of difference between diesel and Antistick ECO.
Laboratory test results, one measurement per variant. These show the effect of the release agent in a direct comparison and cannot be compared with measurements taken on site or with the workplace exposure limit; in those contexts, the values are significantly lower. Whether the limit value is complied with at an installation site depends primarily on the installation temperature, extraction and working methods. We will send you the full test report on request: Request a test report.
A comparison of Diesel and Antistick ECO
| Diesel | Antistick ECO 150 / 150 LV / 170 | |
|---|---|---|
| Laboratory measurement of vapours and aerosols* | 543.5 mg/m³ | 105.9 to 141.1 mg/m³ (74–80 % less) |
| Classification | including: flammable, harmful if inhaled, suspected of causing cancer, toxic to aquatic organisms | Not classified as hazardous according to the safety data sheet |
| Flash point | from 55 °C | above 150 °C (ECO 170: above 170 °C) |
| Transport | Dangerous goods in accordance with ADR (Class 3) | Not classified as a dangerous good under ADR |
| Water hazard class | WGK 2 (significantly hazardous to water) | WGK 1 (self-assessment) |
| Raw material base | Mineral oil | plant-based raw materials (rapeseed oil methyl ester) |
| Effect on bitumen | dissolves bitumen | designed for use as a release agent |
* Laboratory test carried out by TPA GmbH in accordance with IFA Workbook 6305, Method 1, SMA 8 S at 150 °C (test report dated 6 October 2026). Information on Antistick ECO as per the safety data sheet; information on diesel as per the GESTIS substance database.
Which ECO anti-stick coating is suitable?
- Antistick ECO 150: the standard for most applications in asphalt construction.
- Antistick ECO 150 LV: for automatic spray systems with fine nozzles; in laboratory tests, it recorded the lowest reading in the series.
- Antistick ECO 170: thicker consistency, suitable for long transport distances, PmB and multiple loadings.
Switching from diesel in four steps
- Do not top up the diesel and do not mix Antistick ECO with diesel.
- Flush the tank, pipes and nozzles, for example, using Bituclean Extra.
- Insert the test sample: 10 or 20 litres using your own machinery and your own mix.
- Planning the season: Delivery in drums or IBCs, tailored to your requirements.
Request a sample or a quote – or read more about the limit value: AGW bitumen from 2027: What asphalt contractors need to bear in mind regarding release agents.
This article provides an overview and is not a substitute for legal advice or a risk assessment. Last updated: October 2026.